NOT KNOWN DETAILS ABOUT DP50RB

Not known Details About Dp50rb

Not known Details About Dp50rb

Blog Article

The user will not be permitted to open up the covers and panel in the technique, neither Take note: machine disassemble is authorized. To make sure the technique general performance and protection, only Mindray engineers or engineers licensed by Mindray can conduct servicing.

iZoom™ allows exact viewing of image from distance iWorks™ Protocol aids standardize workflow and reduce Examination situations

Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi detail mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.

Permits usage of numerous scanned angles to sort just one picture, resulting in enhanced distinction resolution and enhanced visualization

Web page one hundred forty five Clear control panel Tools: dry delicate cloth, mild soapy drinking water  Process:  Use dry smooth cloth to wash the area of the method. When the program is filthy, moisten the gentle cloth with moderate soapy h2o and wipe off any stains. Use dry smooth cloth to eliminate any humidity and permit all hard surfaces to wholly air-dry. Webpage 146: Clear The Peripherals

three. Click on the higher icon from the display screen (prompts “Update” if you put the cursor on it), the update stage is completed, if fails, make sure you deliver to R&D Heart. Figure six-1 Principal Check Routine maintenance Display 4. Just after update is effective, restart the equipment immediately after power off to help make the info successful. HDD Partition ... Webpage 91 structured report linked data file and DICOM viewing software package Report report template obd.bin OBD info file version.txt Variation file Comment Comment file AnatomyImage Anatomical visuals Measurement Measurement library Doppler application and related boot configuration most important file and plug-ins, remote desktop server Multilanguage string file exe videoplay.

General performance Examination five.5.one Take a look at Approach Resolution Detection depth Geometric Placement Accuracy Blackout area examination File the exam pictures five.5.two Take a look at Content material The graphic applied Here's just for reference, keep on with the image effect in the true Be aware: circumstance. Prerequisites: Show: set the distinction and brightness on the medical software value (or perhaps the default position) Operation natural environment: darkish room, simulating the medical software setting. Page 76 In ailment that the transverse resolution testing targets are horizontally displayed, history the minimum length of two targets that could be Evidently regarded. Repeat the operation earlier mentioned for that transverse resolution testing targets at other depths. As demonstrated in figure beneath. Axial resolution ... Website page seventy seven When using the convex probe, continue to keep the transverse resolution testing targets to NOTE: be exhibited near the midline. When utilizing a linear probe with steer operate, tend not to turn on the steer functionality when complete the transverse resolution exam. Zoom during the region wherever the targets located if needed. The diameter of the concentrate on issue at a specific depth is equivalent towards the transverse resolution on the depth. Webpage seventy eight 5.

five.two.3 Geometric positioning precision Longitudinal geometric positioning precision  Examination Step: Do changes as how in tests the utmost depth. Record the gap by 20mm Every section around the longitudinal targets line utilizing the measurement caliper; Find the worth with the greatest error (to 20mm), estimate the accuracy using the formulation down below The measurement caliper should be positioned on the upper edge of the goal, Observe:... Website page 79 Transverse geometric positioning precision  Exam Step: Deal with the scan floor of the phantom with water or couple gel, Carefully Speak to the probe Along with the scan floor Adjust the depth, creating the transverse targets to get displayed while in the impression. Regulate the main focus position to become posited beside the transverse targets (the standard will not be very clear) Regulate parameters like get, TGC, producing Each individual transverse targets to get clearly shown. Page 80 five.five.two.4 Blackout Space Check Action: Protect the scan area on the phantom with h2o or few gel, Carefully Get in touch with the probe With all the scan surface area Alter the depth at a reduce price, and established the main focus at the closest spot to the scan area. Minimize the value of parameters like AP, Acquire right up until the qualifications noise just might be noticed. Web site 81: Software package Up grade And Servicing

Greatest 4 instances tasking for a person transmitted beam, resulting in great time resolution and better frame amount.

Soon after changing the CPU module, crucial file must be generated once again in accordance with the new MAC handle and penned into HDD on the equipment. Or else, the configuration function on the solution might be lost. Immediately after removing the CPU module, Eliminate panhead screws with washers (12 M3X6) fixed on the key unit box, you usually takes off the board. Web page 118 Figure 8-29 Disassemble the User interface Assembly (one) Maintain the higher fringe of control panel assembly, and open up up the control panel. Figure 8-thirty Disassemble the User interface Assembly (two) Right after taking away one countersunk head self-tapping screw PT3X10 fixed to the control Dp50rb login panel and take out the plug in the keyboard and the principle unit connecting cables, you might take out the user interface assembly.

Page 45 Return “Printer Provider” web page, Find the corresponding provider through the printer list and raise the provider. The method integrates motorists of HP printers, after HP printers are linked, drivers will be mounted immediately (about 10s).If auto installation fails, icon will Show on the appropriate reduced corner on the display screen to alert you that guide set up is essential. Page forty six: Network Preset

This manual may perhaps referring to information and facts protected by copyright or patents and doesn't Express any license under the patent rights or copyright of Mindray, or of others. Site nine: Assertion

A sensible new shape, Improved mobility and practical Procedure make DP-50 well matched for all clinical options.

Observe: On the watch, the brightness adjustment will come prior to contrast. After readjusting the check’s contrast and brightness, change all preset and peripheral options.